SECTION 4 - CONTROL COMPONENTS

3121231

– JLG Lift –

4-15

Operator Programming Mode - (Level-3)

In the Operator Programming Mode the following items
are shown on the main menu (also see Table 4-1):

• Tilt Sensor
• Program

NOTE: There are two production modules available at this

time, one for North/South American and European
languages, and one for Asian languages. All pro-
grammable items between these modules are identi-
cal with the exception of language selection.

Tilt Sensor

Allows viewing current tilt sensor individual X and Y direc-
tion degree reading.

Program

Allows the Operator to program Level-3 items shown in
Table 4-1 following.

Table 4-1. MVL/MSP Ground Control Module - Field Programmable Settings and Factory Preset.

Level-2: Service Level Settings

On LCD Display:

YES =

HIGH =

Level-3: Operator Level Settings

NO =

LOW =

LEVEL

PROGRAMMABLE ITEM

FACTORY PRESET

SETTING RANGE

2

Back to Main

15/20MVL/MSP

Return to Programming Menu

3

Set Language

NOTE: There are two production modules available,

one for North/South American and European
Languages, and one for Asian Languages.

1

1 - English

6 - Italian

2 - German

7 - Swedish

3 - Dutch

8 - Brazilian Portuguese

4 - French

9 - Finnish

5 - Spanish

2

1 - English

3 - Japanese

2 - Chinese

2

Set Maximum Lift Up Speed

100%

0 - 100%

2

Set Maximum Lift Down Speed

100%

0 - 100%

2, 3

Set Sleep Time

5 MINS

0 - 60 MINS

2

Set Polarity Of Left Pot Hole Input 1

2

0 - Disabled / 1 - LOW / 2 - HIGH

2

Set Polarity Of Right Pot Hole Input 2

2

0 - Disabled / 1 - LOW / 2 - HIGH

2

Set Polarity Of Up Limit/Elevation Input

HIGH

HIGH/LOW

2

Set Polarity Of Charger Inhibit

LOW

HIGH/LOW

2, 3

Set Polarity Of The Keypad Code

LOW

HIGH/LOW

2

Set Polarity Of Ancillary Input 1

LOW (a)

HIGH/LOW

2

Set Polarity Of Ancillary Input 2

LOW (b)

HIGH/LOW

2

Load Sensing (LSS)

OFF

ON/OFF

2, 3

Enable Detection Of Horn Open Circuit

NO

YES/NO

2, 3

Enable Detection Of Beacon Open Circuit

NO

YES/NO

2

Enable Obstruction Sensor System (OSS)

NO

YES/NO

2

Enable Detection Of Aux. #1 Open Circuit

NO

YES/NO

2

Enable Detection Of Aux #2 Open Circuit

NO

YES/NO

3

Forward Alarm Disable

NO

YES/NO

3

OSS Diagnostic

NO

YES/NO

2

Zero the On-Board Tilt Sensor

NO

YES/NO

3

View Tilt Sensor Readings

2

Brush Wear Sensor Timer Reset

BLANK/WORN

2

Ancillary 1 Input Inhibit

0

0 - 4

2

Ancillary 2 Input Inhibit

0

0 - 4