Code 04 - Tilt Condition

Check For These Obvious Conditions First:

• If machine is on a tilt of more than 1.5° in either or both the X or Y direction, this is normal operation.

(DRIVE and LIFT UP are disabled when tilt is detected)

• Check if Ground Control Module is mounted securely to the mast support column.

Code 05 - Reserved

Table 6-9. Code 04 - Tilt Condition

STEP

ACTION

SPEC

YES

NO

1.

Using a digital level check the actual level of the machines’ resting surface in
both the X and the Y directions. Does surface check within machine specifi-
cation.

1.5°

X and Y Direction

Go to Step 2

Drive Machine to

Level Surface

2.

At the Ground Control Module, enter the programming mode (See Ground
Control Programming, Section-3 of Service Manual) and check the tilt sen-
sor X and Y readings. Are readings within machine specification?

1.5°

X and Y Direction

Replace Ground

Control Module

Go to Step 3

3.

Zero Tilt Sensor on a surface checked to within 0.0 degrees with a digital
level in both the X and Y directions. (See Ground Control Programming, Sec-
tion-3 of Service Manual).

NOTE: If frequent calibration of the internal Tilt Sensor is required, replace the Ground Control Module.