See table 6-40, Ge 6-36 – JLG 15/20MSP Service Manual User Manual

Page 156

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-36

– JLG Lift –

3121231

Codes (100 - 199) Ground Control Module - Fault Condition

Check For These Obvious Conditions First:

• That all battery and harness connectors secure and undamaged on Ground Control Module.
• Batteries have sufficient charge.
• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-40. Codes (100 - 199) Ground Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval between
each power recycle. Does fault clear?

Done

Go to Step 2

2.

Which code number is displaying?

Code 103

Go to Step 3

Replace

Ground Control

Module

Code 119

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with proper

Batteries

4.

Check battery voltage while charger is operating. Is voltage within specifi-
cation?

Maximum of

31 Volts DC

Replace

Ground Control

Module

Repair or Replace

Battery Charger

5.

Remove the communications cable, P5 connector at the Ground Control
Module and round connector at the Traction Control Module. Check conti-
nuity of all three (3) wires in the communications cable from end to end. P5
- Pins 2, 3, and 4.

Go to Step 6

Repair or Replace

Wire(s)

6.

With communications cable still disconnected at both ends, check for con-
tinuity between Pins 2, 3, and 4 at the P5 connector end.

Repair or Replace

Wires

Go to Step 7

7.

Plug the communications cable on the Traction Control Module to the round
socket on the opposite end of the module. Does this fix problem?

Done

Replace

Ground Control

Module

Advertising