B1

- Lithium battery holder. We recommend replacement when the voltage is lower than 2.5

V, or at least once every three years. We recommend the batteries be replaced with the
PBX off. Before replacement we recommend saving the program of the PBX and the
accounting data in a PC. After replacement check the date, time and program of the
PBX and, if not correct, make the correct adjustment. Never change the batteries when
the PBX is on.
WARNING! Use only a tool made from insulating material for replacement!!!

J1

- connector for connecting extender

J2 – J7

- connectors for connecting line modules (description of modules – see Chapter 5)

J8 – J9

- shorting jumpers (connected – RS232-COM is connected to the J18 connector,

disconnected – RS232-COM is connected to the module VoIP)

J10

- company’s servicing reanimation connector (1 Hz)

J11

- connector for connecting additional memory for announcements (180 s)

J12

- shorting jumper – always fitted (activation WATCH DOG)

J13

- company’s servicing reanimation connector (SW for ALTERA)

J14

- company’s servicing reanimation connector (SW for CPU)

J15

- connector for connecting VoIP module

J16

-.connector for connecting LED signalling

J17

- connector for display

J18

- connector RJ12 with galvanic isolation for PC connection (RS232-COM).

J19

- input voltage connector – (1. +5V, 2.,4. GND, 3. +24V, 5. -24V, 6. RINGV).

J20

- voltage connector – (1. RINGV, 2. -24V, 3. GND, 4. +24V) ).

J21

- output voltage connector – (+24V DC).

J22

- input voltage connector – (+24V DC).

J23

- shorting jumper – always disconnected (only for testing purposes – connection

GND and PGND),

J24

- servicing connector (locking of FLASH memory).

J25

- line input (CINCH – AUX IN) for connecting external music source (for example

CD, radio).


SW1

- Auxiliary RESET1 button (pressing results in reset).

SW2

- Auxiliary RESET2 button (1. –setting company values (press button + switch on
PBX + confirm by pressing again after display of message “Clear config? - push
again/wait“, 2. entry to “service mode” (hold button down during test of RAM
memory).


P1

- regulating volume of line input.


U1

- governing processor

U2-3

- connecting cross-point array.


D1

- signalling +5V

D2

- signalling -12V

D3

- signalling +12V






1

6

1 - RTS
2 - TXD
3 - GND
4 - GND
5 - RXD
6 - CTS

Connecting
up connector
RJ-12 (J18)