Omega lite installation manual – 2N Omega Lite - Installation Manual v1.5 User Manual

Page 22

Advertising
background image

2N

®

- OMEGA Lite

Installation manual


Installation manual

22

www.2n.cz

5.5. Module 1x external line/1xinternal line with 16 kHz tariff pulse

receivers (order No1880032)

This module is completely identical with the previous one but also contains a 16 kHz
tariff pulse receiver (T2). The frequency and sensitivity of the receivers are set
precisely and optimally by the manufacturer. The set sensitivity is approximately -30
dB. Sensitivity can be reduced by removing jumper J1 to approximately -10 dB.
Reducing sensitivity would make sense, for example, if tariff pulses were received
from another line (cross-coupling) or in the case of strong interference (industrial
converters, high-power TV equipment etc.). The LED on the module indicates the
receipt of tariff pulses.


J1

- connector for connecting to motherboard (or to extender module
(connector is secured against incorrect connection by the blanking off
of PIN 5,6,7,8).

J2

- connector RJ-45 (PIN 4-5) for connecting analogue external line.

J3

- connector RJ-45 (PIN 4-5) for connecting analogue internal line.

J4

- company servicing reanimation connector (SW for ALTERA).

J5

- connector for setting impedance (1-2= ETSI, 2-3= 600

Ω).



D1

- signalling LED (picking up, ringing - external line).

D2

- signalling LED (picking up, ringing – internal line).


T1

-CO transformer.

T2

-16kHz transformer.


Note:

Equipment connected to connector J3 (telephone) must comply with the requirements

(standard – type approval) for equipment connected to the unified telephone system.

Advertising