Omega lite installation manual – 2N Omega Lite - Installation Manual v1.5 User Manual

Page 25

Advertising
background image

2N

®

- OMEGA Lite

Installation manual


Installation manual

25

www.2n.cz

5.8. Module ISDN S

0

(Order No 1880020)

The module contains two four-wire interfaces BRI or 2B+D (1x ISDN input, 1x

ISDN BUS), and so two calls can pass through it simultaneously. It is intended for
connecting to the public ISDN network and supports connection in the regime PTP
and PTMP.

In the regime PTP (Point to Point) the code DDI is supported (i.e., as many

sequential numbers as the user requests of the ISDN provider). It is not possible
to attach any further ISDN equipment to the line. The advantage is the possibility
of merging capacity – when several ISDN modules are fitted they can all have the
same code.

In the regime PTMP (Point to MultiPoint) MSN is supported (i.e., upon request it

is possible to allocate up to eight numbers, but it need not be a continuous series
of numbers). It is possible to connect further ISDN equipment to the line (for
example, ISDN card in computer – one number, on the module up to seven
numbers will remain).

We recommend that overvoltage protection be installed to prevent destruction of
the ISDN module by overvoltage.
The control program of the module is stored in a FLASH memory which enables

the updating of the program directly in the PBX.

One of the input RJ45 connectors can be used for simpler creation of an ISDN

bus and thus for the connection of further ISDN equipment (ISDN telephone, fax,
modem).


J1

- connector for connecting to motherboard (or extender module)
(connector is secured against incorrect connection by the blanking off
of PIN 5,6,7,8).

J2

- connector for connecting ISDN line from equipment ISDN NT (end

point).

J3

- connector ISDN BUS.

Advertising