Notes:
•
In no case may system telephones be connected in parallel.
•
LEDs (D1,D2) on the module signal by flashing ongoing communication between the
PBX and system telephone.
•
If the C and D connectors are confused in the system cabling, the system telephone will
not work but will not be damaged.
•
The module is provided with its “own intelligence” – a processor that time balances the
data flow between the main PBX processor and both system telephones. This single-
chip microcomputer is mounted in a socket and can be replaced if necessary.