List of parameters – 2N Helios IP Configuration manual v2.6 User Manual

Page 35

Advertising
background image

35

2N TELEKOMUNIKACE a.s., www.2n.cz

®

List of Parameters

Switch enabled – enable/disable the switch globally. When disabled, the switch
cannot be activated by any of the available codes (including user switch codes),
by a call or quick dial button.

Switch mode – set the monostable/bistable mode for the switch. The switch is

switched off after a timeout in the monostable mode, and switched on with the
first activation and off with the next activation in the bistable mode.
Switch-on duration – set the switch-on time for a monostable switch. This

value is not applied in the bistable mode.
Time profile – assign the switch a time profile to enable switch-on. If the time

profile is inactive, the switch cannot be activated by a code, call or quick dial
button.

Controlled output – assign an electric output to the switch. Choose one of the

available intercom outputs: relay, power output, extender output. If you select

, the switch will not control any electric output but can control external

None
equipment via HTTP commands.
Output type – if you use the

Security Relay module, set the

2N

Helios IP

®

output type to

. In the

mode, the output works in the inverse

Security

Security

mode, i.e. remains closed and controls the

Security Relay module

2N

Helios IP

®

using a specific pulse sequence.

Note

Switch time profiles are available with the Gold or Enhanced Integration
licence only.