5.3.2 Speaker

All the

models are equipped with a speaker or power amplifier output

2N Helios IP

®

to which an external loudspeaker can be connected. Set the phone call and state
signalling volume control in this configuration section. The speaker volume settings are
closely associated with the microphone sensitivity parameters as explained below.

Set the intercom speaker volume and microphone sensitivity values in the Master

,

and

parameters. The values

volume Phone call volume

Microphone sensitivity

can be different for different intercom models as shown in the table below:

Model

Master volume

Phone call
volume

Microphone
sensitivity

Vario

−6 db .. +6 dB (150
mW)

−6 dB .. +18 dB

−6 dB .. +6 dB

Force/Safety
1W

−20 dB .. +16 dB (1
W)

−6 dB .. +18 dB

−6 dB .. +12 dB

Force/Safety
10W

−20 dB .. +20 dB (10
W)

−6 dB .. +18 dB

−6 dB .. +12 dB

Uni

−20 dB .. +16 dB (1
W)

−6 dB .. +18 dB

−6 dB .. +12 dB

Verso

−12 dB .. 12 dB (2 W)

6 dB .. +18 dB

6 dB .. +12 dB

The

parameter controls the general loudness of the device, i.e. call

Master volume

and signal volumes, for example. Set the values with respect to the noise level of the
surroundings. People tend to speak more loudly in noise environments than on quiet
places and so remember that the noisier the surrounding environment, the lower the
microphone sensitivity.

The

parameter controls the reproduced phone call signal loudness.

Phone call volume

Adjust the value if the current master volume is still insufficient for the given
environment. Values higher than +6dB may lead to some signal distortion without
substantially affecting the intelligibility of speech.

The

parameter controls the integrated microphone signal

Microphone sensitivity

loudness and affects the audibility of the intercom user. The microphone sensitivity
value is relative against the automatic microphone sensitivity setting in the Master
volume parameter.