Card reader enabled – enable the card reader function. If disabled, the card
reader ignores all applied cards. If the card is disabled and the Wiegand interface
is OUT, all codes of the used cards are resent to the Wiegand interface.
Associated switch – select a switch to be activated whenever a valid card is
applied.

Accepted HID cards – set the type of HID Prox cards to be accepted by the card
reader. The card reader supports just one card type at an instant. This setting is not
applied if you do not use the HID Prox cards.

Interface mode – enable the Wiegand function and set Wiegand IN/OUT. The
IDs of the cards tapped on the internal card reader are always resent to Wiegand
OUT.
Message format – set the sent/received message format: 26-bit or 32-bit.
Change facility code – set the mode in which the first 8 bits of the 24 card ID
resent to the Wiegand interface are replaced with the value included in the

. The parameter is applied only if the Wiegand is OUT.

Facility code
Facility code
– enter the facility code for card ID resending to Wiegand.

Red LED control – enable the red LED control according to the card reader
digital input states. The values defines the condition under which the red LED
shall be on.