A three-phase direct-to-mains connection topology, B multiple connections topology – ElmoMC SimplIQ Digital Servo Drives-Drum HV User Manual

Page 31

Advertising
background image

Drum HV (High Voltage) Installation Guide

Installation

MAN-DRU-HVIG (Ver. 1.602)

www.elmomc.com

31

3.5.3.3.a

Three-Phase Direct-to-Mains Connection Topology

Figure 6: Non-Isolated Three-Phase Connection Topology

Caution:

Do not connect VN- to PE. In a direct-to-mains connection the VN- must

not be connected to the PE. Connecting the VN- to the PE will cause
irreparable damage to the system.

Be careful and note that in a direct-to-mains connection the Neutral point

is not the most negative voltage level. It is the mid-point level of the
rectified DC bus.

3.5.3.3.b

Multiple Connections Topology

In a multi-axis application it is likely that a single power supply can feed several drives in
parallel.

This topology is efficient and cost saving, by reducing the number of power supplies and the
amount of wiring. Most importantly it utilizes an energy sharing environment among all the
drives that share the same DC bus network.

Advertising