Auxiliary supply (only for s type drive), Environmental conditions, D 4.3.1 – ElmoMC SimplIQ Digital Servo Drives-Drum HV User Manual
Page 71
![background image](/manuals/558396/71/background.png)
Drum HV (High Voltage) Installation Guide
Technical Specifications
MAN-DRU-HVIG (Ver. 1.602)
71
4.3.1.
Auxiliary Supply (Only for S type drive)
Feature
Details
Auxiliary power supply
Isolated DC source only
Auxiliary supply input voltage
18 VDC to 30 VDC
Auxiliary supply input power
≤7 VA (this includes the 5 V/2x200 mA load for
the main and auxiliary encoders)
Note:
An S type drive can only operate if it has an auxiliary supply.
4.4. Environmental Conditions
Feature
Details
Operating ambient temperature
according to IEC60068-2-2
0 °C to 40 °C (32 °F to 104 °F)
Storage temperature
-20 °C to +85 °C ( -4 °F to +185 °F)
Maximum non-condensing humidity
according to IEC60068-2-78
95%
Maximum Operating Altitude
2,000 m (6562 feet)
Mechanical Shock
according to IEC60068-2-27
15g / 11ms Half Sine
Vibration
according to IEC60068-2-6
5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G