Main feedback cable (feedback a) – ElmoMC SimplIQ Digital Servo Drives-Drum HV User Manual

Page 35

Advertising
background image

Drum HV (High Voltage) Installation Guide

Installation

MAN-DRU-HVIG (Ver. 1.602)

www.elmomc.com

35

Figure 10: Feedback and Control Cable Assemblies

Note:

All D-Sub type connectors, used with the Drum HV (High Voltage), should be assembled

in this way.

3.5.6.

Main Feedback Cable (FEEDBACK A)

The main feedback cable is used to transfer feedback data from the motor to the drive.

The Drum HV (High Voltage) can accept any one the following devices as a main feedback
mechanism:

Incremental encoder only

Incremental encoder with digital Hall sensors

Digital Hall sensors only

Interpolated Analog (Sine/Cosine) encoder (option)

Resolver (option)

Tachometer (option)

Potentiometer (option)

Absolute Encoder

FEEDBACK A of the Drum HV (High Voltage) has a high density 15-pin D-Sub socket. Connect
the Main Feedback cable from the motor to FEEDBACK A using a 15-pin, D-Sub plug with a
metal housing. When assembling the Main Feedback cable, follow the instructions in Section
3.5.5 (Feedback and Control Assemblies).

Connector

body

Drain wire

soldered to

the metal
housing

Make sure that the
braid shield is in tight

contact with the metal

housing

Advertising