Chapter 4: technical specifications, Features, Motion control modes – ElmoMC SimplIQ Digital Servo Drives-Drum HV User Manual

Page 66: Advanced positioning control modes, Advanced filters and gain scheduling, Fully programmable, Chapter 4, Technical specifications

Advertising
background image

Drum HV (High Voltage) Installation Guide

MAN-DRU-HVIG (Ver. 1.602)

www.elmomc.com

66

Chapter 4:

Technical Specifications

This chapter provides detailed technical information regarding the Drum HV (High Voltage).
This includes its dimensions, power ratings, the environmental conditions under which it can be
used, the standards to which it complies and other specifications.

4.1. Features

The Drum HV (High Voltage)'s features determine how it controls motion, as well as how it
processes host commands, feedback and other input.

4.1.1.

Motion Control Modes

Current/Torque - up to 14 kHz sampling rate

Velocity - up to 7 kHz sampling rate

Position - up to 3.5 kHz sampling rate

4.1.2.

Advanced Positioning Control Modes

PTP, PT, PVT, ECAM, Follower, Dual Loop, Current Follower

Fast event capturing inputs

Fast output compare (OC)

Motion Commands: Analog, Pulse-Width Modulation (PWM), digital (SW) and Pulse and

Direction

4.1.3.

Advanced Filters and Gain Scheduling

“On-the-fly” gain scheduling of current and velocity

Velocity and position with “1-2-4” PIP controllers

Automatic commutation alignment

Automatic motor phase sequencing

4.1.4.

Fully Programmable

Third generation programming structure with motion commands – “Metronome”

Event capturing interrupts

Event triggered programming

32 KB memory

Advertising