8 updating the software, Updating the software – INFICON HLD6000 Refrigerant Leak Detector User Manual

Page 51

Advertising
background image

6 Operation

51

Tr

an

sl

ation

o

f the

o

rig

in

al

operatin

g

in

str

u

ct

io

ns

HLD

6000

, k

ina4

3

e1-

a

, 140

8

Interval for calibration request,

see "6.3.6 Set time interval for calibration request",

page 36

,

Calibration factor,

see "6.4.6 Calibration", page 43

(can be changed by the service

team),

Config. Analog outputs 1 - 2,

see "6.3.8.2 Configuring analog outputs", page 37

,

Configuration PLC Outputs 1 - 8,

see "6.3.8.5 Configuring PLC outputs", page 37

,

Configuration PLC Inputs 1 - 10,

see "6.3.8.6 Configuring PLC inputs", page 38

,

Volume,

see "6.3.3 Adjust volume", page 34

,

LR setpoint 1,

see "6.4.1 Setting setpoints", page 41

,

LR setpoint 2,

see "6.4.1 Setting setpoints", page 41

,

Display measured value,

see "6.3.5 Setting the display", page 35

,

Module on the M12 socket,

see "6.3.8 I/O module", page 36

,

Phase,

see "6.4.6 Calibration", page 43

(can be changed by the service team),

Calibration leak external,

see "6.4.6.3 Calibration with an external calibration leak",

page 45

,

Interface unit leakage rate,

see "6.3.8.7 Setting the interface unit", page 38

,

Sniffer light alarm config.,

see "6.4.2 Setting up the sniffer probe", page 41

,

Sniffer light brightness,

see "6.4.2 Setting up the sniffer probe", page 41

,

Sniffer key configuration,

see "6.4.2 Setting up the sniffer probe", page 41

,

Setpoint audio alarm,

see "6.4.3 Setting up an alarm profile for setpoints", page 41

,

Record interval,

see "6.4.8 Measured data", page 47

,

Memory location,

see "6.4.8 Measured data", page 47

,

Language,

see "6.3.1 Setting the language", page 34

,

Time,

see "6.3.2 Setting date and time", page 34

,

Value axis decades,

see "6.3.5 Setting the display", page 35

,

Value axis grid,

see "6.3.5 Setting the display", page 35

,

Time axis scale,

see "6.3.5 Setting the display", page 35

,

2 To change individual parameters, press on an entry on the touch screen.

3 Either confirm changes with

or reject them with the

key.

6.8

Updating the software

Software updates from INFICON are installed with the aid of a USB stick. The update func-
tion of the device can be found under "

> Update".

An update is possible,

 if one or several updates are available on the USB stick, but only one update per type

at most (basic unit, operating unit, sniffer line, I/O module),

 if in the case of the "sniffer line" or the "I/O module" these parts are also connected free

of disturbances and have an update function.

The corresponding keys in the update menu such as "Basic Unit", "Operating Unit", "Sniffer
Line" and "I/O Module" are active and can be activated individually. Inactive buttons can
be recognized as they are in gray.