background image

Chapter 3

Menus

3-23

Pocket Wait: This parameter has two functions, depending on the setting of the Pocket
Ready signal in I/O setup. If no Pocket Ready input is programmed for an output, then
this is the time the program waits for the indexer to complete its move. After the wait
time, deposit begins.

If a Pocket Ready input is programmed for an output, then this is a timeout value. If the
pocket ready signal is not received within Time Wait, then an error occurs.

Dev Graph Limit: Sets the upper limit for the Rate Deviation graph Y axis.

Rate Alarm Low: Sets the % deviation below rate setpoint that causes an audible
alarm.

Rate Alarm High: Sets the % deviation above rate setpoint that causes an audible
alarm. The tone of the high rate alarm is lower than that of the low rate alarm.

Password Enable: If Password is enabled, the Quick Start, Film and System Menus
require a password. The Process Menu can be used to select a process, but a
password is required to make any changes on the Process Menu.

Password: If password is enabled, this parameter sets the sequence of SoftKeys to
press to enter menus. Press the desired sequence to set the password. Holding down
the top and bottom switch while powering up the SQC-222 sets the password to “1111.”

System Time: Sets the SQC-222 clock to your local time. System time is battery
backed up. Does not compensate for daylight savings time.

System Date: Sets the SQC-222 date to your local time. System date is battery
backed up.