Acre Meter (Optional)

The battery operated acre meter operates in one of two

modes. In sleep mode, the display is blank and the
counter is accumulating acres. Sleep mode will be
entered if a button is not pressed for 20 seconds. In entry
mode, the display is on and the operator can enter
values. To get into entry mode, press the FUNC button.

To Program Meter

1.

Press the FUNC button to scroll to pulses screen.

2.

Enter the number of pulses for the model as listed on
the following page using the up or down button. See

Table 3-4.

3.

Press the FUNC button to set pulses. (If the screen
goes blank before you press the FUNC button,
repeat steps 1 & 2).

4.

Press the FUNC button to scroll to screen width.

5.

Enter the width of seeder for the model as listed on
the following page using the up or down buttons.

6.

Press the FUNC button to set width. (If the screen
goes blank before you press the FUNC button,
repeat steps 4 & 5).

7.

Press the FUNC button to scroll through screens to
check that the correct pulses and width have been
entered.

To Enter Password

1.

Press the FUNC button to scroll to the pass screen.

2.

Pick a number and enter it by using the up or down
buttons.

3.

Press the FUNC button to set password; the number
screen will show (set): record this number, it will be
required if you need to disable your password.

4.

Let screen go blank - password is now entered.

To Disable Password

1.

Press the FUNC button to scroll to pass screen - it
will show (ent).

2.

Use up or down button to enter password (number).

3.

Press the FUNC button to scroll around to pass
screen again. Number entered in step 2 will appear.

4.

Press up or down to enter 0.

5.

Press the FUNC button; (dis) will appear. Password
is now disabled.

Special Notes

• When the meter is set to the “count” mode on the

pulses screen, meter will register only magnetic
wheel revolutions.

• Meter must be in sleep mode (blank screen) to

calculate or count pulses.

• Count screen must have a value other than zero

(0000) to scroll to other modes or screens.

• To reset FIELD ACRES screen to zero (0000), press

the up and down buttons simultaneously.

Table 3-4: Pulse Table

MODEL

Pulses

Per Acre

Pulses

per 1000

sq.’

Width

SSPT604

293

67

5

SSP4

578

13

4

SSP5

578

13

5

SSP6

578

13

6

SSP8

SS8

764

18

8

SSP10

SS10

764

18

10

SSP12

SS12

764

18

12

SSP108

SS108

760

17

8

SSP110

SS110

760

17

10

SSP112

SS112

760

17

12

SSP208

SSP2081

SS208

SS2081

764

18

8

SSP210

SSP2101

SS210

SS2101

764

18

10

SSP212

SSP2121

SS212

SS2121

764

18

12

Advertising