Operation

4.12 Delete a file stored in the Programmer

With this function you delete the parameter files stored in the EPM Programmer

Press

The display shows...

Explanation

1.

MENU

DELETE FILE

Press the key until the menu appears in the display.

2.

ENTER

SELECT FILE

This request is briefly shown in the display

>#DEFAULTS(400

)

<

The cursor is blinking in the display on the right.

3.

>#ABC_ _ _ _ _(400

)

<

Select the parameter file you want to delete (e.g.

ABC_ _ _ _ _).

4.

ENTER

CONFIRM=[ENTER]

Press the MENU key, if you want to abort the

process.

5.

ENTER

DELETING FILE…

FILE DELETED!

The parameter file is deleted.

DELETE FILE

The EPM programmer automatically returns to the

main menu.

4.13 Change EPM Programmer Internal Configuration

With this function, you can change the type of files that the EPM Programmer can EDIT by downloading the proper

configuration for the file you will be working with from a “Configuration EPM” loaded in the MASTER PORT.

Press

The display shows...

Explanation

1.

MENU

LOAD CFG EPM

Press the key until the menu appears in the display.

2.

ENTER

VERIFYING MASTER

The programmer verifies that the EPM in the

MASTER PORT is a valid Configuration EPM.

CONFIRM=[ENTER]

Press the ENTER button to confirm this action

3.

ENTER

TRANSFERRING 0%...100%

The new configuration is loaded into the EPM

Programmer’s memory and verified.

4.

WAIT-LOADING CFG
CFG LOADED!
LOAD CFG EPM

Messages are displayed briefly then the EPM

programmer automatically returns to the main

menu.

Tip!

• Changing the EPM Programmer’s internal configuration is only required if you are going to EDIT an inverter drive

file stored in the EPM Programmer or EDIT a servo drive EPM. The Programmer must be configured for the

parameter version of the file.

• Configuration EPM’s can be purchased from Lenze, AC Tech or your local distributor.

• Configuration files can be downloaded into the EPM Programmer from your PC via RS232 connection using

TECHLINK software.