Commissioning, 3 operation with external power supply, Stop – Lenze EPM Programmer EEPM1RA User Manual

Page 9: 7english, 6 vdc

Advertising
background image

7

ENGLISH

Commissioning

3.3 Operation with external power supply

Stop!

• Avoid electrostatic discharges (ESD) at the connector for the voltage supply. EPM programmer malfunction

may occur.

• Take appropriate measures to avoid electrostatic conditions.

• Occasionally occurring malfunctions can normally be remedied by switching the EPM Programmer off and then

on again.

It is also possible to operate the EPM programmer with an external power supply.

Power supply output data:

• Output voltage: 6 VDC, stabilized

• Output current: 300 mA

Power supply connector plug details

For connections to the EPM programmer the power supply

unit requires an extra-low voltage plug with the following

dimensions: 2.1 Ч 5.5 Ч 9.5 mm.

Connect the power supply unit

A

Type EEPM1RA

For deta led nformation refer

to nstruction manual EP01x

EEMP1RA 1A 10

Made in USA
EPM Programmer

L

L STED

IND

CONT EQ

5D81

xxxxx xx xx

6VDC 150mA min
Power Supply

FRIWO 7207 06 15 0791 MPP15)

epm006

Plug the extra-low voltage plug of the power supply into the A connector at the back of the EPM Programmer

+6 VDC

epm005

Advertising