Preface and general information

1.3 EPM Technology and Operation

The EPM uses EEPROM technology housed in a removable plastic

casing for protection and ruggedness. A removable memory

structure, as provided by an EPM include:

• Programming a drive without power.

• Easily duplicate proven programs using the EPM Programmer.

• Reduce down-time and troubleshooting.

The EPM feature is included with several Lenze and AC Tech inverter

drive controllers and in the new SimpleServo products. Operation and

some functionality differ between the Drive and Servo product lines.

epm011

Drive Controllers

EPM Color: Blue
EPM files can be stored in EPM Programmer

Servo Controllers

EPM Color: Blue (Model 94)
EPM files cannot be stored in EPM Programmer

OEM Defaults

The EPM, when used in Inverter Drive Controllers, actually contains two sets of drive parameters. The USER memory is

the memory the drive typically uses for operation and is actually the drives operating memory that can be accessed and

changed from the front of the drive, a remote keypad or serial communications. The OEM Default values can only be written

by the EPM Programmer and cannot be altered through normal drive operation or programming. This provides a benefit

in that an OEM using the EPM Programmer to quickly copy the drive configuration, actually ships the drive with their own

“Factory Defaults”.

Lenze Servo Controllers are programmed using MotionView94 Software via serial link with a PC. Field reprogramming from the

front of the controller is not possible. As such, resetting to OEM defaults is impossible and this second memory set is not used.

1.4 Pictographs used in these Operating Instructions

Pictograph used

Signal words

Stop!

Warns of possible malfunctions of the EPM Programmer due to

electrostatic discharge (ESD)

Tip!

Designates a general and useful note. If observed, it will make using the

EPM Programmer easier.

1.5 Scope of delivery

Scope of delivery

Important

• 1 EEPM1RA EPM programmer with 4 batteries (already

installed)

• 1 Operating Instructions

After receipt of the delivery, check immediately whether

the items delivered match the accompanying papers.

Lenze does not accept any liability for deficiencies claimed

subsequently.

Claim

• visible transport damage immediately to the forwarder.

• visible deficiencies / incompleteness immediately to

your Lenze representative.