2.1 General data and application conditions

Field

Values

Type of Protection

IP20

Permissible temperature ratings

Operation

0 … +50 °C

Transport

-20 … +60 °C

Storage

-20 … +60 °C

Humidity

<85 %, without condensation

Weight

1.3 kg with batteries

Applied Standards

Noise emission to EN 50081-2: 1993

Noise immunity to EN 61000-6-2 : 1999

Approvals

UL 508C

Underwriters Laboratories

Power Conversion Equipment

Conformity

CE

EMC Directive (89/336/CEE)

2.2 Electrical Data

Field

Values

DC Voltage Supply

+ 6 VDC, min. 150 mA

Internal Batteries

4 mono-cells (type D), 1.5 VDC each

External power supply unit

+ 6 VDC, 300 mA

Display

Type

LCD

Display format

Text

Lines x characters

1 x 16

Contrast setting

Via menu

Memory

Data Memory

up to 120 parameter files for inverter

drive controllers

Serial Interface

DB9 Connector

RS232