Technical data 2 technical data, 1 general data and application conditions, 2 electrical data – Lenze EPM Programmer EEPM1RA User Manual
Page 6: 4english

4
ENGLISH
Technical data
2
Technical data
2.1 General data and application conditions
Field
Values
Type of Protection
IP20
Permissible temperature ratings
Operation
0 … +50 °C
Transport
-20 … +60 °C
Storage
-20 … +60 °C
Humidity
<85 %, without condensation
Weight
1.3 kg with batteries
Applied Standards
Noise emission to EN 50081-2: 1993
Noise immunity to EN 61000-6-2 : 1999
Approvals
UL 508C
Underwriters Laboratories
Power Conversion Equipment
Conformity
CE
EMC Directive (89/336/CEE)
2.2 Electrical Data
Field
Values
DC Voltage Supply
+ 6 VDC, min. 150 mA
Internal Batteries
4 mono-cells (type D), 1.5 VDC each
External power supply unit
+ 6 VDC, 300 mA
Display
Type
LCD
Display format
Text
Lines x characters
1 x 16
Contrast setting
Via menu
Memory
Data Memory
up to 120 parameter files for inverter
drive controllers
Serial Interface
DB9 Connector
RS232