Electrical installation

Important notes

4

l

37

EDK94ZPS113 DE/EN/FR/ES/IT 4.0

(

Stop!

No device protection if the mains voltage is too high
The mains input is not internally fused.
Possible consequences:

ƒ

Destruction of the device if the mains voltage is too high.

Protective measures:

ƒ

Observe the maximally permissible mains voltage.

ƒ

Fuse the device correctly on the supply side against mains
fluctuations and voltage peaks.

)

Note!

Switching operations on the motor side of the controller are
permitted for safety switch−off (emergency off).
Please observe:

ƒ

When the controller is enabled, switching operations may lead to
a response of the controller monitoring functions.

ƒ

The switching elements on the motor side must be rated for DC
voltages with U

DCmax

= 800 V.