Electrical installation – Lenze E94AZPS User Manual
Page 44
Advertising

Electrical installation
Wiring
Terminal assignment
l
44
EDK94ZPS113 DE/EN/FR/ES/IT 4.0
1
0
2
3
a
b
c
d
e
M5
U
V
W
BD1/T1
BD2/T2
PE
SSP94MOTL1
Fig. 4−4
Stripping lengths of the motor cable
Dimensions [mm]
Type
a
b
c
d
e
Device size 1
80
8
25
150
8
Device size 2
90
8
30
160
8
Device size 3
100
10
30
170
8
How to proceed:
1. Strip the motor cable
0 according to dimensions given.
2. Fold back the shield of the motor cable
1 over the cable sheath.
3. Stabilise the shield with self−adhesive conductive foil
2
(recommendation).
4. Fix the shield and conductive foil with heat−shrinkable tube
3 on the
cable sheath.
5. Fasten cable lugs or wire end ferrules.
6. Connect the shields separately to the shield sheet using shield clamps (no
strain relief).