Electrical installation

Wiring
Terminal assignment

4

l

44

EDK94ZPS113 DE/EN/FR/ES/IT 4.0

1

0

2

3

a

b

c

d

e

M5

U
V
W

BD1/T1
BD2/T2

PE

SSP94MOTL1

Fig. 4−4

Stripping lengths of the motor cable

Dimensions [mm]

Type

a

b

c

d

e

Device size 1

80

8

25

150

8

Device size 2

90

8

30

160

8

Device size 3

100

10

30

170

8

How to proceed:
1. Strip the motor cable

0 according to dimensions given.

2. Fold back the shield of the motor cable

1 over the cable sheath.

3. Stabilise the shield with self−adhesive conductive foil

2

(recommendation).

4. Fix the shield and conductive foil with heat−shrinkable tube

3 on the

cable sheath.

5. Fasten cable lugs or wire end ferrules.
6. Connect the shields separately to the shield sheet using shield clamps (no

strain relief).