Electrical installation

Wiring
Terminal assignment

4

l

42

EDK94ZPS113 DE/EN/FR/ES/IT 4.0

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Device sizes 1 + 2:
flexible
with wire end
ferrule

2.5

12

0.5 ... 0.6

4.5 ... 5.3

PZ0

Device size 3:
flexible
with/without wire
end ferrule

10/16

6

1.2 ... 1.5

10.6 ... 13.3

PH1

External brake resistor

Terminal X105
(left part)

Labelling

Description

Rb1
Rb2

External brake resistor

SSP94LX105

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Device sizes 1 + 2:
flexible
with wire end
ferrule

2.5

12

0.5 ... 0.6

4.5 ... 5.3

PZ0

Device size 3:
flexible
with/without wire
end ferrule

10/16

6

1.2 ... 1.5

10.6 ... 13.3

PH1