Electrical installation – Lenze EMF2179IB User Manual

Page 59

Advertising
background image

Electrical installation

Cable specification

6

EDKMF2179 DE/EN/FR 4.0

59

l

H2 Kabelspezifikation−Thincable

Features of the data line

Conductor pair

At least copper 18; at least 19 cores (individually tinned)

Insulation diameter

3.81 mm (nom.)

Colours

Light blue, white

Pair windings / m

Approx. 10

Shielding/conductor pair

2000/1000, Al/Mylar, Al side on the outside, w/shorting fold (for
tensile load)

Impedance

120

W

+/− 10 % at 1 MHz

Capacitance between conductors

39.37 pF/m at 1 kHz (nom.)

Capacitance between one conductor and
another which is connected to the shield.

78.74 pF/m at 1 kHz (nom.)

Capacitive assymetry

3937 pF/km at 1 kHz (nom.)

Spec. DC resistance at 20 °C

22.64

W

/km (max.)

Damping

0.43 dB/100 m at 125 kHz (max.)
0.82 dB/100 m at 500 kHz (max.)
1.31 dB/100 m at 1.00 MHz (max.)

Features of the voltage line

Conductor pair

At least copper 15; at least 19 cores (individually tinned)

Insulation diameter

2.49 mm (nom.)

Colours

Red / black

Pair windings / m

Approx. 10

Shielding/conductor pair

1000/1000, Al/Mylar, Al side on the outside, with w/shorting fold (for
tensile load)

Spec. DC resistance at 20 °C

11.81

W

/km (max.)