6 troubleshooting and fault elimination, 1 error messages, Error messages – Lenze EPM-H510 User Manual

Page 72: 6troubleshooting and fault elimination, Troubleshooting and fault elimination

Advertising
background image

Troubleshooting and fault elimination

L

72

EDBEPM-H510 DE/EN/FR 4.0

6

Troubleshooting and fault elimination

6.1

Error messages

Call up the status messages of the keypad to see the last error message.

(% 60)

Display (

ERROR

) Error

Cause

Remedy

NO ERROR

No error

-

-

PR ERROR

Faulty data

exchange

Faulty connection between

keypad and PC

•

Check connection

•

Check cable

COM BROK

Communication

interrupted

Serial data cable between

keypad and PC defective or

not properly connected

•

Check Sub D plug connection

•

Replace serial data cable

ASI

ko1

Communication

•

Faulty system bus wiring

•

Check wiring ( + 55 )

ASIC ko1

Communication

ith

t

•

Faulty system bus wiring

(

l it

l)

•

Check wiring ( + 55 )

ASIC ko2

with system

bus (CAN)

y y

g

(e.g. polarity reversal)

•

Faulty parameter setting

g (

)

•

Check parameter setting ( + See

“HMI Designer Getting Started”

ASIC ko3

bus (CAN)
interrupted

•

Faulty parameter setting
for interface (baud rate,

“HMI Designer - Getting Started”
Manual )

ASIC ko4

interrupted

for interface (baud rate,

address, identifier)

Manual )

RESET

address, identifier)

SDOERR 6

SDOERR 5

SDOERR 3