EDBEPM-H510 DE/EN/FR 4.0

Battery replacement

3

2

+

1

2

3

4

h510_011

Fig. 7-2

Battery replacement

1.

Lift clip

(

and take out the battery

)

2.

Insert the new battery (clip is plus connection)

Close housing cover

0

0

1

N.C.

CAN+

Shield

CAN-

V-

1 2 3 4 5

1

2

3

4

INPUT VOLTAGE: 18-32 VDC 15 W

FUSE 800 mA

3 V LITHIUM CELL TYPE CR2032

LCD brightness adj.

MSP

+24 VDC

0 VDC

1

2

3

4

N. C.

h510_008

Fig. 7-3

Close housing cover

1.

Put housing cover back, and tighten screws

&

2.

Attach terminal strips

'