Commissioning, With hand terminal – Lenze EDK71MMXXX−020 User Manual

Page 106

Advertising
background image

7

Commissioning

With hand terminal

EDK71MMXXX−020 DE/EN/FR 5.0

L

106

The

user menu − The 10 most important drive parameters at a glance

After every mains connection with connected hand terminal or connecting the hand terminal during
operation to the AIF interface, the 10 codes specified in the

user menu (Code C0517) are immediately

available.

The

user menu is set to all codes at the factory to allow for commissioning a standard application:

Code

Designation

Lenze setting

C0054 Apparent motor current of

motor 1

Display only

C0055 Apparent motor current of

motor 2

Display only

C0006 Transfer HW/hand terminal

0

Setting the acceleration time (C0012) and starting voltage
(C0016) via potentiometer, setting the rated motor current
(C0120) via stepping switch

C0120 Rated current

Rated motor current for I

2

t monitoring

1 Motor 1

Accepts the value from the stepping switch:

l

If C0006 = 0, 2, 4, 6:
– Display only

l

If C0006 = 1, 3, 5, 7:
– Rated current can be set via C0120

2 Motor 2

C0410 Configuration of digital input

signals

1 Motor 1 start/stop

1

X3/E1

2 Motor 2 start/stop

2

X3/E2

3 Brake control

3

X3/E3

4 ... 24

255

Not assigned

C0415 Configuration of digital

output signals

1 X3/A1

3

Status of motor 1

2 X3/A2

4

Status of motor 2

3 X3/A3

5

Status of brake

4 X3/A4

25

TRIP error message

5 ... 6 AS−I output bit

255

Not assigned

C0012 Motor voltage acceleration

time

Time for voltage change U

0

... U

mains

1 Motor 1

Accepts the value from potentiometer "T"

l

If C0006 = 0, 1, 2, 3:
– Display only

l

If C0006 = 4, 5, 6, 7:
– Acceleration time can be set via C0012

2 Motor 2

C0423 Delay time of "Release

brake"

0.00 s

C0424 Delay time of "Apply brake"

0.00 s

C0002 Parameter set management

See code table