Reversal of direction of rotation, Electrical installation – Lenze EDK71MMXXX−020 User Manual

Page 90

Advertising
background image

5

Electrical installation

Reversal of direction of rotation

EDK71MMXXX−020 DE/EN/FR 5.0

L

90

(

Stop!

Connect the supply cable in correct phase relation.

If the mains phases are switched at the supply terminals, error message

Er252

(

a

) or

Er253

(

e

) appears.

26

BN

Z Z Z Z

GND

+

-

20 28

E1

7

E2 E3 E4 E5

A1 A2 A3 A4

A+ A-

7 59 59

X3

T1 T2

X3

X3

B1 B2

2W

2V

2U

1W

1V

1U

+24 V DC

(+18 VDC - 0 % … +30 VDC + 0 %,

200 mA ... 1.5 A)

7

20

7 7

20

-X1

M

3~

J>

PTC

M

3~

L1
L3

N

3/N/PE AC 100 … 550 V

45 … 65 Hz

L2

PE

L1 L2 L3

}

+

3.4 Nm

30 lb-in

Æ

4.3 mm

X3

0.2 Nm

1.7 lb-in

£

1.5 mm

2

³

AWG 16

6mm

X1

X1

X1

2.9 Nm

26 lb-in

.0 mm

AWG 10

2

£

£

4

6mm

X1

start226

Terminal

Function (bold = Lenze setting)

Data

X1/L1, L2, L3

Mains connection

X1/1U, 1V, 1W

Motor connection

X1/2U, 2V, 2W

X1/B1, B2, BN Connection of Lenze spring−operated brake BFK457 or

BFK458

^ 26

X1/

*

Support terminal (e.g. for star point), not assigned