Commissioning, Code table – Lenze EDK71MMXXX−020 User Manual

Page 114

Advertising
background image

7

Commissioning

Code table

EDK71MMXXX−020 DE/EN/FR 5.0

L

114

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0002

s

uSEr

(Cont.)

Transfer
parameter sets
with keypad

Keypad

ð

PAR3 (+ FPAR1)

Overwrite the selected
parameter set and FPAR1, if
necessary, with the
corresponding data of the
keypad

73

with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

13

with all other function modules

Keypad

ð

PAR4 (+ FPAR1)

74

with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

14

with all other function modules

Drive controller

ð

keypad

Copy all available
parameter sets
(PAR1 ... PAR4, if necessary
FPAR1) into the keypad

80

with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

20

with all other function modules

Keypad

ð

function module

Overwrite only the
module−specific parameter
set FPAR1 with the
corresponding data of the
keypad

40

with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

Function module

ð

keypad

Copy only the
module−specific parameter
set FPAR1 into the keypad

50

with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

C0002

s

uSEr

(Cont.)

Save separate
basic setting

9

PAR1

ð

separate basic setting

You can save a separate
basic setting for the
parameters of the drive
controller (e.g. the delivery
state of your machine):
1. Ensure that parameter

set 1 is active

2. Inhibit the controller
3. Set C0003 = 3, confirm

with

v

4. Set C0002 = 9, confirm

with

v

, the separate

basic setting is stored

5. Set C0003 = 1, confirm

with

v

6. Release the controller

Load/copy
separate basic
setting

5

Separate basic setting

ð

PAR1

Restore separate basic
setting in the selected
parameter set

6

Separate basic setting

ð

PAR2

7

Separate basic setting

ð

PAR3

8

Separate basic setting

ð

PAR4