23

MK-145

TROUBLESHOOTING

TROUBleSHOOTiNG:

Turn the

ON/OFF switch to the OFF position and unplug the saw from the power

source before performing any troubleshooting procedure.

Motor Stops Turning:

WARNING

(A)

If not fully connected,

reconnect plugs and

turn on the saw. If fully

connected, go to step B

(E)

If power source is not at

120V move the saw to

another circuit and

turn on the saw

(B)

If the GFCI is tripped reset

it and turn on the saw. If

the GFCI is not tripped,

go to step C

(C)

If the circuit breaker is not

15 amps, move the saw to

a 15-amp circuit breaker

and turn on saw. If the

circuit breaker is 15 amps,

go to step D

(D)

If tripped, reset the

breaker once and turn on

the saw. If the saw trips

again, proceed to step F.

If the circuit breaker is not

tripped, go to step E