Setup, adjustment and operation, Setup, Pre-start inspection – MK Diamond MK-2000 User Manual

Page 15: Connecting the water pump

Advertising
background image

MK-2000

Revision 03/05, Effective Date March 21, 2005

Page 15

SETUP, ADJUSTMENT and OPERATION

SETUP:

1. Pre-start Inspection:

Prior to beginning work, a pre-start inspection of the saw should be performed.









































2. Connecting the Water Pump:

1.

To prevent the possibility electrical shock, the MK-2000 MUST be de-energized when
connecting the Water Pump.

2.

To prevent the possibility of electrical shock, use only MK Diamond qualified replacement parts

NOTE: To prevent pump damage, the Water Pump must be disconnected if cutting with a Dry Blade.



















(A)

Ensure the ON/OFF Switch is

in the OFF position

(B)

Verify the Movable Cutting

Table moves freely along the

Guide Rails

(C)

Inspect the Diamond Blade

for damage, cracks and de-

bonding; verify the blade is

correct for the material being cut

(A)

Connect the Cooling Transfer

Tube to the inlet connection of

the Blade Guard

(B)

Connect the Water Pump

power cord to the connection

found on the back of the motor

ON/OFF

Switch

De-bonding

of segment

Cracks

Verify ease of movement

(See Maintenance section

if problems exist)

(D)

Inspect the Pump Assembly for

damage – ensure the cord is

free of cracks or cuts

(E)

Inspect the MK-2000 for

damage – ensure the cord is

free of cracks or cuts

Inspect for

damage

Inspect for

damage

Inspect for

cracks or cuts

OFF

Position

Cooling

Transfer Tube

Press on

Inlet

Connection

Install

Plug

Pump

Connection

Replace if excessively grooved

(See Maintenance Section)

(E)

Inspect the Wooden Protective

Strip for excessive grooves

Advertising