Setup, adjustment and operation, Water pump setup for operation, I. external water source – MK Diamond MK-2000 User Manual

Page 16: Ii. re-circulation

Advertising
background image

MK-2000

Revision 03/05, Effective Date March 21, 2005

Page 16

SETUP, ADJUSTMENT and OPERATION

3. Water Pump Setup for Operation:

The Water Pump can be setup for operation in two ways, External Water Source or Re-circulation.

NOTE: If using a dry blade for operation, DO NOT connect the water pump.

I. External Water Source:

This is the preferred method of cooling.









































II. Re-circulation:

NOTE: When using the re-circulation method, the water should be changed often for longer pump life.



















Drain Plug

(A)

If not installed, install the Drain

Plug into the Water Pan

(B)

Place the Water Pump in the

back of the Water Pan

(C)

Fill the Water Pan until water

completely covers the Water

Pump suction

Cover Pump

Suction

(A)

Verify or remove the Drain plug

from the Water Pan

(B)

Place the Water Pump in an

external container

(C)

Fill the external container until

water completely covers the

Water Pump suction

Drain Plug

External Water

Container

(D)

Place an external catch basin

below the Water Pan drain hole

Catch

Basin

Water Pump

in container

Cover Pump

Suction

Water
Pump

Advertising