Maintenance and troubleshooting, Cooling flow, Return to mk diamond for repair – MK Diamond MK-2000 User Manual

Page 35

Advertising
background image

MK-2000

Revision 03/05, Effective Date March 21, 2005

Page 35

MAINTENANCE AND TROUBLESHOOTING























5. Cooling Flow:













































(A)

Check Cooling Flow Adjusting

Valve open

(C)

Place Pump into a bucket of

water and check flow

(B)

Remove the Cooling Transfer

Tube from the Blade Guard inlet

(D)

Remove the Cooling Transfer

Tube and check flow

(E)

Remove the Pump Discharge

Fitting and check

(F)

Remove the Pump Intake

Screen and check for debris

Go to

Step C

If flow exist,

go to Step E

Pull Tab

to loosen

If flow exists,

go to Step A

Pull to

Remove

If flow exists,

go to Step F

Remove

Discharge Fitting

If Screen clean,

go to Step G

(E)

Check power source voltage is

115V (240v if running at 240v)

– if not 115v move to another

circuit

(D)

Verify Circuit Breaker is not

tripped; if tripped, reset the

Circuit Breaker once

If circuit breaker

not tripped go to

Step F

Check Breaker

tripped

If circuit breaker

not tripped go to

Step F

Check for

correct circuit

voltage

If tripped, reset

once if trips again,

go to step F

Return to

MK Diamond

for Repair

(F)

Return to MK Diamond

Pull to

Remove

If flow exists,

go to Step D

Cover Pump

Suction with

water

Pull Intake Screen

to remove