MK-2000

Revision 03/05, Effective Date March 21, 2005

Page 34

MAINTENANCE AND TROUBLESHOOTING

3. Vibration:








































4. Blade Stops Turning:























(C)

Remove the V-belt

(B)

Remove the Belt Guard

(A)

Remove the Diamond Blade

and recheck vibration

(D)

Clean Motor and recheck

vibration

Remove

Belt Guard

Phillips

Screwdriver

Go to

Step C

If vibration exists,

go to step E

Diamond

Blade

If vibration exists,

go to step B

If no vibration exists,

replace Blade

Go to

Step D

Return to

MK Diamond

for Repair

(E)

Return to MK Diamond

V-belt

(A)

Allow motor to cool at least five

minutes and then depress

motor Overload Reset Switch

(B)

Verify all power connections

are fully installed

If less than 20

Amps move saw

to 20 Amp circuit

Overload

Reset Switch

If motor does not

start, go to Step B

Check all

connections

If all plugs connected,

go to Step C

If circuit 20 Amp

or greater go to

Step E

Check Breaker

20 Amps or

greater

(C)

Verify the circuit breaker is at

least 30 amps – if not, move to

30-amp circuit