Setup, adjustment and operation – MK Diamond MK-2000 User Manual

Page 17

Advertising
background image

MK-2000

Revision 03/05, Effective Date March 21, 2005

Page 17

SETUP, ADJUSTMENT and OPERATION

4 MK-2000 Setup for Operation:

1. Before powering or starting, check for damage that could prevent this equipment from proper

operation or performing it’s intended function. Check for binding and alignment of moving parts.
Check for damaged, broken, or missing parts.

2. Verify the On/Off switch is in the OFF position.
3. Before connecting the MK-2000 to a power supply, be sure the voltage, cycle and phase of the

job site power source meet one of the requirements of TABLE 3

VOLTAGE: 115v/240v
CYCLE: 60hz
PHASE: 1-phase

TABLE 3

4. If using an extension power cord, make sure the length and wire gauge correspond to he

requirements listed in TABLE 1 on page 9. An extension power cord that is too small in wire
gauge (diameter), or too long in length, will cause the motor to overheat and could cause
premature failure.

5. Do not cover the motor vents as this could lead to motor overheating.

NOTE: In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

Portable Generator:
If using a portable generator to provide power, ensure the generator meets the following minimum
requirements:

8 KW

120/240 volts

66.7/33.3 amps

Single Phase

FOR DUAL VOLTAGE MODELS ONLY ! The MK-2000 motor has 2 voltage positions, 115v and
240v. Ensure the Voltage Adjustment Switch of the MK-2000 motor is set for the voltage of the
intended power source BEFORE installing the MK-2000 Power cord.





































ON/OFF

Switch

(A)

Ensure the ON/OFF Switch is

in the OFF position

(B)

Verify or place the Voltage

Adjustment Switch in the correct

voltage position (See the

Maintenance Section)

(C)

Locate the correct power source

for the setting of the MK-2000

Voltage Adjustment Switch

(D)

Align, install and twist to lock the

Polarized plug of the MK-2000

into the correct power source

Turn clockwise

to lock

Voltage Adjustment

Switch

OFF

Position

115v Power

Source

240v Power

Source

Advertising