PX-3 PAVER EXTREME
MAINTENANCE
CLEANUP
Clean the Air Filter and PX-3 surfaces after each use. The following section describes the correct procedure for
cleaning your PX-3.
1.
2.
3.
4.
5.
Unplug the PX-3 from its power source.
Remove the Motor Filter Cap (Figure 25). The Filter Cap pops on and off without removing the retaining screws.
Clean the Filter by removing it from the Filter Cap (Figure 26) and tapping it on a hard surface, or use
compressed air (Figure 27).
Reinstall Filter into Filter Cap and replace it on the PX-3 Motor (Figure 28).
Clean the remainder of the PX-3 by wiping its surface with a clean cloth.
Fig. 26 Remove Filter
Fig. 25 Remove Motor Filter Cap
ALWAYS wear eye protection when using compressed air.
CAUTION
Fig. 27 Clean up Filter by
tapping it on a hard surface or
using compressed air
Fig. 28 Reinstall Filter into Filter
Cap and place them back onto the
PX-3
Fig. 19 Loosen Wingnut