1.
2.
3.
4.
5.
6.

Unplug the PX-3 from its power source and set it up for operation (see Inspection and Setup section).
Locate and remove one Motor Brush Cap (Figure 38). There is one Brush on either side of the Motor.
Remove the Motor Brush. Clean and brush Housing (Figure 39).
Align and install the new Motor Brush (Figure 40).
Install the Motor Brush Cap (Figure 41).
Change the second Motor Brush by repeating the same steps listed above (Figure 42).

MOTOR BRUSH CHANGE OUT

Disconnect the tool before servicing and when changing accessories, such as blades, bits, cutters and the like.

WARNING

Fig. 39 Clean and brush Housing

Fig. 38 Remove Motor Brush Cap

Fig. 41 Install Motor Brush Cap

Fig. 42 Repeat for other Motor Brush

When installing the Motor Brushes, care must be taken to ensure the Spring End is straight before installing the
Motor Brush Cap.

NOTICE

Fig. 40 Install new Motor Brush