How To Warm Up Station Hydraulics

MTS Series 793 Tuning and Calibration

Tuning Procedures

53

How To Warm Up Station Hydraulics

It is good practice to warm up station hydraulics before tuning (or testing) by
exercising the actuator without a specimen. Remove any specimen and run the
system in displacement control for at least 30 minutes using a 80% full-scale
length command at about 0.1 Hz.

1. Select the following settings in the function generator.

Standalone FlexTest SE Controllers: Select Tuning > Manual > FG

Automated Controllers: Click

on

Station Manager:

A crush zone exists between the actuator and any equipment in the path of
its movement. Immediate and unexpected actuator response is possible
when you apply hydraulic pressure to your system.

Unexpected actuator movement can cause injury to personnel, damage to
equipment, or both.

Stay clear of the actuators when applying hydraulic pressure.

C

ONTROL

S

ETTING

Control Channel
(Automated Controllers
only)

The control channel associated with the

valve you are adjusting.

Control Mode

Displacement

Adaptive
Compensator

None

Target Setpoint

0

Amplitude

80% of the full-scale actuator displacement

Frequency

0.1 Hz

Wave Shape

Sine

WARNING