Go to + daq + detection activity – MTS TW Elite User Manual

Page 35

Advertising
background image

About detector action resources

Actions are test resources. By default, the only action available to the detectors in the example test is No
Action. The MTS Insight controller also supports Program Hold, Program Stop, and Interlock actions, but
these actions have been removed from the test because they are not used.

About restoring detector actions

You can restore unused controller resources to tests by importing them with the controls in the Resources
tab (Define tab > Resources subtab). In

Modify the Example Test

(p. 81), you will restore all controller

actions to the example test.

For More Information

Modify the Example Test

(p. 81)

Go To + DAQ + Detection Activity

This composite activity performs multiple functions associated with the following tabs:

Go To

DAQ

Limit Detection

Break Detection

Wait for Operator Action

For most tests, including the example test, the command content of the test is provided by one or more
Go To + DAQ + Detection activities in the Run section.

Go To tab

The Go To tab is configured to ramp the crosshead at a rate defined by the Test Rate variable. The
Termination Condition on this tab is not enabled, so the ramp is configured to continue until a specimen
failure is detected by the condition specified in the Break Detection tab. If that condition is not detected,
the ramp continues until one of the other branches of the Parallel Branch activity (such as a limit detection
branch) completes.

MTS TestSuite | 35

Examine the Example Test