4. In the Properties panel, enter the following:

Go To + DAQ + Detection Activity Properties

Value

Property

Enter “Apply Program Command”

Display Name

Note:

The controls that follow
are in the Go To tab.

Right-click Rate and select Edit to display
the Edit Variable window. In the Edit

Rate

Variable window, change the Default
Value
to 3 mm/s.

Enable (check)

Termination Condition

1.00 kN

Value

Enable (check)

Brake Distance

100 N

Value

Runtime effect

Modified properties are configured to ramp the crosshead at a rate of 3 mm/s until either:

MTS TestSuite | 91