2 module management mode, Module management mode – Omnitron Systems Technology Converter GXTM User Manual User Manual

Page 29

Advertising
background image

4.2

MODULE MANAGEMENT MODE

From the Module configuration screen, the management mode can be changed. Select option 18 to change
the mode. The management mode options will be displayed.

PI

Module - iConverter GX/TM iConverter, Serial Agent

Identifier -

Chassis Number =

1

Switch ON Condition

OFF Condition

H/W

Actual

Slot Number =

2

1: Fiber Manual

Fiber AN

Off

Off

Model Number =

8923-1

2: UTP Manual

UTP Auto-Neg

Off

Off

3: UTP 10/100

UTP 1000

Off

Off

Serial Number =

xxxxxxxx

4: UTP 10 Mbps

UTP 100 Mbps

Off

Off

Manufacturing Date = xxxxxxxx

5: UTP HDX

UTP FDX

Off

Off

Hardware Revision = xx

6: Link Propagate

Link Segment

Off

Off

Software Revision = xx

7: Remote Fault

Normal

Off

Off

8: Symm Fault Det

Normal

Off

Off

LED

9: BP A Enabled

BP A Disabled

Off

Off

1: Power =

On

10: BP B Enabled

BP B Disabled

Off

Off

2: Power Supply 1 =

Off

11: Pause Enabled

Pause Disabled Off

Off

3: Power Supply 2 =

On

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3 =

Off

13: UTP Manual-X

UTP Auto-X

Off

Off

5: Fiber Link =

Off

14: UTP Crossover

UTP Through

Off

Off

6: BP Master =

Off

15: Not Available

7: UTP 100+10 Link = Off

16: Not Available

8: UTP 1000+10 Link= Off

OAM settings:

9: UTP FDX =

Off

17: IP Protocol State Off

18: Management Mode Auto ah

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >

Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3

The GX/TM module supports several management options. Option 18 configures how the module will
communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol. The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol. This option provides an industry standard
method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.

NOTE: See NetOutlook User Manual for complete information on the management modes.