To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow
the instructions to enter the chassis number.

To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow
the instructions to enter the chassis name.

NOTE: When the NMM is installed into the chassis and is set to Remote OAM, the chassis number
of the GX/TM is automatically assigned by the NMM.

PI

SA

IP and Control Preferences Screen

iConverter, Serial Agent

1: Set IP

192.168.1.220

2: Set Subnet Mask

255.255.255.0

3: Set Gateway

192.168.1.1

4: Chassis Number

1

5: Chassis Name (also sysName)

GX/TM

6: Enable/Disable TELNET

Enabled

7: Enable/Disable FTP

Disabled

8: Enable/Disable Soft Switch Reload

Disabled

9: TELNET Password

*****

10: FTP Password

11: Serial Password

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.

3.4.1.4

Setting GX/TM Passwords

The GX/TM is shipped from the factory without password protection on the Serial Console Port. It is
highly recommended that the network administrator set a password in order to prevent unauthorized access
to the unit. The password can be any 1-32 character alphanumeric string.

The GX/TM is shipped from the factory with Telnet enabled and FTP disabled. From the IP and Control
Preferences
screen, select 6 to enable or disable Telnet, and select 7 to enable or disable FTP.

To set the password for Telnet access, select 9 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to enter and verify the password. The default password for Telnet
access is “public”.

To set the password for FTP access, select 10 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to enter and verify the password.

To set the password for serial access, select 11 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to enter and verify the password.