8 cnode loopback, 9 port statistics, Cnode loopback – Omnitron Systems Technology Converter GXTM User Manual User Manual

Page 43: Port statistics, Page 43

Advertising
background image

4.3.8

cNode Loopback

The GX/TM has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent
recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode
equipment is required to obtain performance metrics.

cNode configuration is accessed by selecting option 10 from the Port configuration screen.

PI

SA

cNode Control -iConverter GX/TM iConverter, Serial Agent

Identifier -

Chassis Number = 1 Slot Number = 3 Model Number = 8923-1

1: cNode Loopback Disabled

2: cNode Rate Limit 64 Kbps

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

From the menu, loopback can be enabled or disabled and the rate limit can be selected.

4.3.9

Port Statistics

The GX/TM module provides port statistics on both the fiber and UTP port.

The Port Statistics can be viewed by selecting option P from the Module configuration screen.

PI

Module - iConverter GX/TM iConverter, Serial Agent

Identifier -

Chassis Number =

1

Switch ON Condition

OFF Condition

H/W

Actual

Slot Number =

2

1: Fiber Manual

Fiber AN

Off

Off

Model Number =

8923-1

2: UTP Manual

UTP Auto-Neg

Off

Off

3: UTP 10/100

UTP 1000

Off

Off

Serial Number =

xxxxxxxx

4: UTP 10 Mbps

UTP 100 Mbps

Off

Off

Manufacturing Date = xxxxxxxx

5: UTP HDX

UTP FDX

Off

Off

Hardware Revision = xx

6: Link Propagate

Link Segment

Off

Off

Software Revision = xx

7: Remote Fault

Normal

Off

Off

8: Symm Fault Det

Normal

Off

Off

LED

9: BP A Enabled

BP A Disabled

Off

Off

1: Power =

On

10: BP B Enabled

BP B Disabled

Off

Off

2: Power Supply 1 =

Off

11: Pause Enabled

Pause Disabled Off

Off

3: Power Supply 2 =

On

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3 =

Off

13: UTP Manual-X

UTP Auto-X

Off

Off

5: Fiber Link =

Off

14: UTP Crossover

UTP Through

Off

Off

6: BP Master =

Off

15: Not Available

7: UTP 100+10 Link = Off

16: Not Available

8: UTP 1000+10 Link= Off

OAM settings:

9: UTP FDX =

Off

17: IP Protocol State Off

18: Management Mode ah OAM

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl > P