3.4.1.2

Setting IP Parameters as DHCP Client

To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The
Other Networking Features screen will appear.

PI

SA

Management Options

iConverter, Serial Agent

Network Management

1: Chassis and Module Management

2: Set Module Identifier

Management Module Preferences

3: IP and Control Preferences

4: SNMP Preferences

5: Abandon Preference Changes

6: Save Preference Changes

7: Restore to Factory Defaults

8: Restart Management Module

9: Other Networking Features

Management Module Maintenance

10: Firmware Update

11: Set Date/Time

IP Address = 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 9

PI

SA

Other Networking Features Screen iConverter, Serial Agent

1:

Enable/Disable DHCP Client

Disabled

2:

Enable/Disable Keep Alive Trap

Disabled

3:

Keep Alive Trap interval (10-600 secs)

10

4:

Enable/Disable SW1 Switch Block

Enabled

5:

Serial Baud Rate

57600 bps

6:

Enable/Disable VLAN Support

Disabled

7:

VLAN ID (0-4095)

2

8:

VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts
to enable DHCP.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.

3.4.1.3

Setting the Chassis Number and Name

A Chassis Name, or sysName, can be assigned for identification of the GX/TM in the SNMP client. The
name can be any 1-32 character alphanumeric string.

The Chassis Number can remain as 1 (factory default) when the GX/TM is installed without an iConverter
NMM in the same chassis. When the GX/TM is installed in the same chassis as an NMM, then the GX/TM must
be set to the Chassis Number of the NMM.