“Incomplete”, Discovery is in process, but is not yet completed.

Multiplexer State - Indicates the Multiplexer state (“Discard”, “Forward” or “Unknown”) of the remote
ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs to the lower sublayer.
If “Discard”, the remote partner is discarding non-OAMPDUs network frames. If “Unknown”, the
Multiplexer state of the remote partner is indeterminate.

Parser Action - Indicates the Parser Action state (“Discard”, “Forward” or “Loopback”) of the remote
ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs network frames to
the higher sublayer. If “Loopback” is displayed, the remote partner is looping back non-OAMPDUs
network frames. If “Discard” is displayed, the remote partner is discarding non-OAMPDUs network
frames.

Critical Event - Indicates the Critical Event state (“Yes” or “No”) of the remote partner. If “Yes” is
displayed, the local device has detected a Critical Event. If “No”, the local device has not detected a
critical event.

Link Fault - Indicates the remote partner has detected a fault in the receive direction (“Yes” or “No”). If
“Yes” is displayed, the receive link is down. If “No”, the receive link is up.

OAM Mode - Indicates the OAM mode (“Active” or “Passive”) of the remote partner.

Supports - Indicates the supported options (Variable Access “Var”, Link Event Notification “Events”,
Loopback “LB” or blank if no options are supported) of the remote partner.

OUI - Indicates the three hex byte IEEE organizational specific identifier (or blank if unknown) of the
remote partner.

802.3ah parameters can be accessed by selecting options 7 from the Port configuration screen. The fiber
configuration screen is displayed.

PI

SA

802.3ah Control -iConverter GX/TM iConverter, Serial Agent

Identifier -

Chassis Number = 1 Slot Number = 3 Model Number = 8923-1 Port = 1

1: 802.3ah OAM State

Disabled

Local Status

2: OAM Mode

Passive

Discovery State

Incomplete

3: Loopback Mode

Disabled

Multiplexer State

Disabled

4: Loopback Timeout

30 sec

Parser Action

Unknown

5: Unidirectional Mode

Not Available

Remote Status

Discovery State

Unknown

Critical Event

Unknown

Link Fault

Unknown

Multiplexer State

Unknown

Parser Action

Unknown

Mode

Unknown

Supports

Unknown

OUI:

00:00:00

Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >

To configure the 802.3ah parameters for the UTP port, type an n and press <ENTER>.