Warning – MacDon D60 Draper Headers User Manual

Page 96

Advertising
background image

SECTION 8. MAINTENANCE AND SERVICING

Form 169441

94

Revision B

8.7.2 SICKLE

REMOVAL

WARNING

Stand to rear of sickle during removal to
reduce risk of injury from cutting edges. Wear
heavy gloves when handling sickle.

a. Stroke sickle to its outer limit, and clean area

around sickle head.

b. Remove zerk from pin (A).

c. Remove nut and bolt (B).

d. Insert screwdriver in groove of pin (A), and pry up

on sickle head pin to free sickle. Pin does not
have to be removed from arm.

e. Seal bearing in sickle head with plastic or tape.

f.

Wrap a chain around sickle head, and pull sickle
out.

NOTE

For single drive sickles with splice plate,
remove bolts from splice plate and pull
sickle out from both ends.

8.7.3 SICKLE

HEAD

BEARING

REPLACEMENT

8.7.3.1 Bearing

Removal

a. Remove sickle. Refer to previous section.

b. Using a flat-ended tool (D) with approximately the

same diameter as the plug (E), tap out the seal
(F), bearing (G), and plug from the underside of
the head (shown at top of next column).

NOTE

The seal can be replaced without
removing the bearing. When changing
seal, check pin and needle bearing for
wear. Replace if necessary.

8.7.3.2 Bearing

Installation

a. Place O-ring (C) and plug (E) in sickle head.

IMPORTANT

Install the bearing with the stamped
end (the end with identification
markings) against the tool.

b. Using a flat-ended tool (D) with approximately the

same diameter as the bearing (G), push the
bearing into the sickle head until the top of the
bearing is flush with the step (H) in sickle head.

c. Install seal (F) in top of sickle head with lip facing

outwards.

IMPORTANT

To avoid premature sickle head or
wobble box failure, be sure there is no
looseness in:

• Fit of sickle head pin and needle

bearing, and

• Fit of sickle head pin and pitman arm.

B

A

H

REMOVAL

C

D

H

G

F

E

Advertising
This manual is related to the following products: