2mechanical, Mechanical, 2 mechanical – MacDon R85 Rotary Disc 16 Foot Self-Propelled Windrower Headers User Manual

Page 170

Advertising
background image

TROUBLESHOOTING

8.2 Mechanical

Symptom

Problem

Solution

Section

Bent cutter blade

Replace blade.

Replacing the Cutter
Blades, page 132

Conditioner roll timing off

Check roll timing and
adjust if necessary.

6.4 Roll Timing, page 71

Excessive noise

Conditioner roll gap too
small

Check gap and adjust if
necessary.

Increase roll gap.

6.2 Roll Gap, page 67

Conditioner rolls
contacting each other

Check roll timing.

6.4 Roll Timing, page 71

Auger center support
loose

Tighten bolts on support.

6.12.1 Adjusting the
Overshot Auger, page 90

Excessive vibration or
noise in header

Mud deposits on
conditioner rolls

Clean rolls.

Excessive heat in
cutterbar

Too much lubricant in
cutterbar

Drain lubricant and refill
with specified amount.

7.5.8 Lubricating the
Cutterbar, page 121

Mud on cutterbar

Remove mud from
cutterbar. Do not allow
mud to dry on cutterbar.

Spindle bearing failure

Replace spindle bearing.

See MacDon Dealer.

Material wrapped around
spindle

Remove disc and remove
material.

7.6 Cutterbar Disc
Maintenance, page 126

Cutting too low in rocky
field conditions

Decrease header angle.
Increase float.

6.6 Header Angle, page
78

and

6.1 Header Float,

page 65

Ground speed too high
in rocky field conditions.
At High ground speed,
header tends to dig rocks
from ground instead of
floating over them

Reduce ground speed.

6.8 Ground Speed, page
81

Blade incorrectly mounted

Check all blade mounting
hardware ensuring blades
are free to move.

Inspecting Cutter Blades,
page 130

Frequent blade damage

Header float set too heavy Increase float.

Machine pulling to one
side

Header dragging to one
end and pulling to that
side

Adjust header float on
both ends.

6.1 Header Float, page 65

169457

162

Rev. F

Advertising