RKI Instruments GasWatch 2 Manual User Manual

Page 17

Advertising
background image

GasWatch 2 Operator’s Manual

Operation • 12

1. Make sure the GasWatch 2 is in Measuring Mode. The current gas

concentration should be displayed on the LCD.

2. Press and release the POWER/MODE button to enter Peak Display

Mode. This will activate the LCD backlight and display the Peak
reading. A small Peak symbol is displayed in the upper left corner of the
LCD.

3. Press and release the POWER/MODE button again to enter STEL

Display Mode. This will display the STEL reading. The word “STEL” is
displayed in the middle of the LCD above the reading.

4. Press and release the POWER/MODE button again to enter TWA

Display Mode. This will display the TWA reading. The word “TWA” is
displayed in the middle of the LCD above the reading.

5. Press and release the POWER/MODE button once again to return to

Measuring Mode.

NOTE: If you do not press a button for 20 seconds while displaying the

Peak, STEL, or TWA readings, the unit will return to Measuring
Mode automatically and the backlight will turn off.

Displaying the Min and Max (GW-2X)

You can display the minimum (Min) and maximum (Max) readings on the
GW-2X when the GasWatch 2 is in Measuring Mode using the POWER/
MODE button. The Min and Max readings are cleared when the unit is
turned off.

1. Make sure the GasWatch 2 is in Measuring Mode. The oxygen

concentration should be displayed on the LCD.

2. Press and release the POWER/MODE button to enter Min Display

Mode. This will activate the LCD backlight and display the Min reading.
A small Min symbol is displayed in the upper left corner of the LCD.

3. Press and release the POWER/MODE button again to enter Max

Display Mode. This will display the Max reading. A small Max symbol is
displayed in the upper left corner of the LCD.

4. Press and release the POWER/MODE button once again to return to

Measuring Mode.

NOTE: If you do not press a button for 20 seconds while displaying the

Min or Max readings, the unit will return to Measuring Mode
automatically and the backlight will turn off.