Control terminal block, English-10, Control wiring block diagram – Rockwell Automation 25D PowerFlex 40P Quick Start - FRN 1.xx - 3.xx User Manual

Page 10: Enbl

Advertising
background image

English-10

Control Wiring Block Diagram

See Control Wiring Block Diagram Notes on next page.

Control Terminal Block

04

05

06

07

01

02

03

08

09

11

12

13

14

15

16

17

18

19

Digital Common

Digital Input 1

Digital Input 2

Digital Input 3

Stop

(1)(6)

Start/Run FWD

(2)

Direction/Run REV

(3)

Digital Input 4

Opto Common

R1

R2

R3

Relay N.O.

Relay Common

Relay N.C.

+24V DC

+10V DC

0-10V (or ±10V) Input

(4)

Analog Common

4-20mA Input

Analog Output

Opto Output 1

Opto Output 2

RS485 Shield

+24V

+10V

Typical

SNK Wiring

Typical

SRC Wiring

1

RS485

(DSI)

R1 R2 R3

SNK

SRC

0-10V

0-20mA

01 02 03 04 05

11 12 13 14 15

06 07 08 09

16 17 18 19

(1)

Enable Jumper

(6)

30V DC
50mA
Non-inductive

Common

24V

ENBL

Enable

(6)

Jumper

(5)

Pot must be
1-10k ohm
2 Watt Min.

0-10V

0/4-20mA

Analog Output Select

Voltage Range Select

SRC

SNK

10V

+/-10V

(4)

30V DC

125V AC

240V AC

Resistive

3.0A

3.0A

3.0A

Inductive

0.5A

0.5A

0.5A

Advertising